Chapter 10 Testing Lipsync
2. Perform steps 2 - 6 of
to set up analyzer for lipsync testing.
3. Press the Tools key. The Tools menu appears on the 882's display as shown below.
System
Sequence
Probe
AFC
4. Choose the Analyzer item by pressing the adjacent soft key. The Analyzer menu
appears on the 882's display as shown below.
Timing
*
CableTest
ViewPix
5. Choose the LipSync item by pressing the adjacent soft key. The LIPSYNC menu
appears on the 882's display as shown below.
LIPSYNC
!
Measure
!Report
Note: Be sure that you have transferred any existing Lipsync reports to your PC.
Otherwise, generating a new report overwrites the existing report.
6. Choose !Report item by pressing the adjacent soft key. A Lipsync Measurements
Report is generated and stored on the PCMCIA card in the
/card0/Library/Reports/LipSync_Data.htm file.
Alternatively, to generate a lipsync measurement report through the command line
interface, enter the following command:
LSAX:RPTG 1
// generate lipsync measurement report
LSAX:LSGU
// Activates lipsync analyzer
7. Open the FTP Browser on the 882 and select a suitable directory on your PC to store
the report.
8. Using the FTP Browser, transfer the report from the 882 PCMCIA card to your PC like
shown below.
"Testing HDMI source device for Lipsync
Reports
ImgShift
Analyzer
PIX-ERR
PRN-ERR
LipSync
!
Exit
handling" on page 325