326
Appendix A Command Reference
EQUalization interval Before vertical sync pulse
Format parameter setting - synchronization
Establishes the width of the equalization interval before the vertical sync pulse in each
field whenever a serrated and equalized sync type is selected via either
commands and selected via the
sync signal is one of the CCIR types, then the actual equalization interval output by the
generator will be 0.5 lines shorter than the whole number specified. The EQUB? query
returns the current setting of EQUB.
EQUB lines
lines
min = 0
max = number of lines after video and before vertical sync
EQUB?
lines
The
FMTU
command instructs the generator to use the new setting. The
updates hardware to the new setting and redraws the test image.
EQUB 3
// Set pre-equalization to 3 lines in buffer
FMTU
// Update hardware to current buffer contents
SSST
command. If the type specified for the selected
ASCT
or
DSCT
ALLU
command