FSPD
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Example
882 Video Test Instrument User Guide (Rev A.35)
Frame Sync Pulse Delay
Format parameter setting - Synchronization
Sets the delay of the frame sync pulse relative to the last line of active video in the current
format. The FSPD? query returns the current FSPD setting.
FSPD delay
delay
min = 0 lines
max = (VTOT/SCAN) line
FSPD?
delay
To get a pulse, frame sync must first be enabled with the
command instructs the generator to use the new settings. The
the hardware to the new settings and redraws the test image.
FSPG 1
// Enable Frame Sync
FSPP 1
// Set for positive going pulse
FSPW 20
// Make the pulse 20 pixels wide
FSPG 300
// Pulse to occur 300 lines after
// the last line of active video
FMTU
// Update hardware to new settings
FSPG
command. The
FMTU
ALLU
command updates