124
Chapter 13 Testing HDCP on HDMI
XVSI
4
// Activates the HDMI-H interface
ALLU
// Applies the interface setting to the 882
3. Press the Interface key repeatedly until the following menu appears:
HDMI IN 1
*
HDMI IN 2
4. Choose the HDMI IN 1 by pressing the adjacent soft key.
5. For the 882EA when using the EST, verify that the source is sending in video using the
timing measurement function of the analzyer. Refer to
external HDMI/DVI source signal on a
the timing test.
Verify that the source is outputting one of the following formats: 1) 640x480p at
59.94/60Hz; 2) 720x480p at 59.94/60Hz; 3) 720x576p at 50Hz.
Verify that the source is outputing the RGB color space.
If the 882EA cannot detect the incoming video, enter the following command to turn on
the EST:
QD:PROD:EST
6. (For Front Panel Operation) Press the Tools key and choose the Reports item by
pressing the adjacent soft key.
The following is displayed on the 882's LCD.
EDID
Misc
7. Select HDCP to access the HDCP compliance test menu.
The following is displayed on the 882's LCD.
!CompRpt
8. Select EditPCP to define the capabilities of the HDCP device under test.
The following is displayed on the 882's LCD.
1.2
:CTS Ver.
Source
:DUT Type
+1A-01
:Test Num-
+1
:Src Max KSV
display:" on page 246 for information on running
// Turns on the EST.
Packets
HDCP
EditPCP
-