VSPW
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Example
882 Video Test Instrument User Guide (Rev A.35)
Vertical Sync Pulse Width
Format parameter setting - Synchronization
Establishes the width of the vertical sync pulse in lines. If the type specified for the
selected sync signal (see SSST, ASCT, DSCT, or
types, then the actual sync pulse width output by the generator will be 1/2 line shorter than
the whole number specified. The VSPW? query returns the current setting of VSPW.
VSPW lines
VSPW?
lines
The
FMTU
command instructs the generator to use the new setting. The
updates hardware to the new setting and redraws the test image.
VSPW 3
// Set V sync width to 3 lines in buffer
FMTU
// Update hardware to current buffer contents
DSST
commands) is one of the CCIR
ALLU
command
573