USIZ
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Example
882 Video Test Instrument User Guide (Rev A.35)
Unit of measure used for physical SIZes
System control
Sets the units of measure assumed by
physical size of the image that appears on the CRT (context sensitive; see
FMTE). The USIZ? query returns the current setting of USIZ.
Note: Changing the USIZ parameter between inches and millimeters will convert the
current HSIZ and VSIZ values to match the new unit of measure. For example, if USIZ is in
inches and the current HSIZ is 10 (inches), changing USIZ from inches to mm will change
HSIZ to 25.4 (mm). The USIZ command should be sent before specifying physical sizes in
format command files.
USIZ units
units
0 = sizes not given (use default)
1 = inches
2 = mm
USIZ?
units
The
ALLU
command updates hardware to the new setting and redraws the test image,
taking the new units into account.
FMTB
// Begin editing session
// One or more format editing commands ...
USIZ 1
// Select inches as unit of measure in buffer
HSIZ 10.4
// Set width to 10.4 in buffer
VSIZ 7.8
// Set height to 7.8 in buffer
ALLU
// Test the new settings
// One or more format editing commands ...
FMTE
// End editing session
HSIZ
and
VSIZ
commands to establish the
FMTB
and
561