246
Chapter 8 Working with Test Sequences
3. Set the sequence path to the sequence directory on the generator's flash memory or
the PC card. For example, to set the path to the generator's flash memory, enter the
following command:
SEQP
/tffs0/Library/Sequence
To set the sequence path to the PC card, enter the following command:
SEQP
/card0/Library/Sequence
4. Establish a session with the generator using either HyperTerminal over a serial
connection or Telnet over an Ethernet LAN. See
the
882" on page 30 or
5. Transfer the text file to the generator. For example, to transfer the file using
HyperTerminal, do the following:
a. On the Transfer menu, click Send Text File. The Send Text File dialog box
appears.
b. Select the text file you want to send, and then click Open. HyperTerminal displays
the commands as they are sent.
c. Press Enter once to ensure that the last command is sent.
"Establishing a Telnet session with the
"Establishing a terminal session with
882" on page 33.