Quantum Data 881 User Manual page 487

Hide thumbs Also See for 881:
Table of Contents

Advertisement

882 Video Test Instrument User Guide (Rev A.35)
12. Press the Tools key get back to the Reports menu.
The 882 LCD will display the reports menu as shown below.
EDID
Misc
13. Select HDCP to access the HDCP compliance test menu.
The following is displayed on the 882's LCD.
!CompRpt
14. Select !CompRpt to initiate the HDCP compliance test. Initiate each test individually.
The message "HDCP Compliance Test" is shown and then all the tests are shown in
sequence.
Refer to
"To view the HDCP compliance
view the generated report.
Alternatively, to run a specific test you can use the command line as shown below:
CPTX:CPTR 31
CPTX:CPTU
You can query the complete list of tests to choose from:
CPTX:GCTN?
You can query the currently selected test to run with:
CPTX:CPTR?
Packets
HDCP
EditPCP
report:" on page 605 for procedures on how to
// Selects specific test (e.g. 3C-I-01) see
table below
// Initiates the execution of the test
// Queries the list of tests supported
// Queries the selected test to run (see table)