Quantum Data 881 User Manual page 975

Hide thumbs Also See for 881:
Table of Contents

Advertisement

XISH:TTYP
Class
Description
Command syntax
Query syntax
Query response
Example 1
Example 2
Related commands
882 Video Test Instrument User Guide (Rev A.35)
Image SHift Trace TYPe
Image Shift
Establishes the way in which image shifting will occur. A repeating trace type causes the
image to shift between the start and end points, and then restart at the start point. A
reverse trace type causes the image to shift between the start and end points, and then
from the end point to the start point. If an imageshift editing session is in progress (the
ISHB
command was issued), the trace type will be changed, but not applied to the
hardware until the
ISHE
take effect immediately.
XISH:TTYP type
type
1 = Repeat
2 = Reverse
XISH:TTYP?
1 or 2
XISH:TTYP 1
//Sets the trace type to 1, Repeat.
XISH:TTYP?
//Queries for current trace type.
1
ISHA, ISHB, ISHE, ISHG, ISHK, ISHL, ISHN, ISHP, ISHQ?, ISHS, ISHU, XISH:HINC,
XISH:PATH, XISH:SRCN, XISH:TINC,
and
ISHU
commands are issued. Otherwise, the command will
XISH:VINC
597

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

882

Table of Contents