Environmental Conditions; Temperature And Humidity; Table 2-17 Power Consumption - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Basic Chassis – CD-CP00 Chassis
Basic Chassis + Expansion Chassis
Basic Chassis + 2 Expansion Chassis
Basic Chassis + 3 Expansion Chassis
5.3
System Hardware Manual

Table 2-17 Power Consumption

Chassis

Environmental Conditions

5.3.1

Temperature and Humidity

Chassis, Telephones, BCH, BHA, 8LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F
(-20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – PZ-BS10, PZ-BS11, PZ-VM21 Daughter Board, PZ-ME50
Daughter Board, PZ-IPLA/IPLB Daughter Board, CD-8DLCA with
PZ-8DLCB Daughter Board, CD-16DLCA
Operating Temperature: +32°F ~ +104
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Maximum
Voltage
RMS
Current
110VAC
2.35A
220VAC
1.19A
230-240VAC
1.15A
110VAC
4.7A
220VAC
2.38A
230-240VAC
2.3A
110VAC
7.05A
220VAC
3.57A
230-240VAC
3.45A
110VAC
9.4A
220VAC
4.76A
230-240VAC
4.6A
Issue 9.0
Watts Used
Watts Used
(Idle)
(Maximum)
96
130
192
260
288
390
384
520
o
o
o
F (0
C ~ 40
C)
2 - 21

Advertisement

Table of Contents
loading

Table of Contents