Issue 9.0
4 - 26
Each node in a NetLink network requires the
PZ-ME50.
CD-CP00 without the PZ-ME50 installed,
supports a single chassis system (six slots only).
CD-CP00 with the PZ-ME50 is required to
support a system with multiple chassis.
CD-CP00 without the PZ-ME50 supports only
(one) CD-LTA (8 Digital Station/2SLT) blade.
Failure to properly install and program ports
higher than 64 (as described below) can corrupt
the SV8100 database.
When the PZ-ME50 is not physically installed
on the CD-CP00, do not attempt to change the
PCPro database configuration to indicate that
the PZ-ME50 is installed on the CD-CP00,
Program ports 64 and higher, and then upload
the PCPro configuration to the SV8100 system.
This process can cause the SV8100 database to
be corrupted. Refer to the next bullet for the
proper installation/programming procedure.
To properly install and configure the
PZ-ME50; first install the PZ-ME50 on the
CD-CP00. To program the ports above 64 using
PCPro, perform a new download before
attempting to program the ports.
If the PZ-ME50 is installed on the CPU at a later
date, a system upgrade must be performed using
the CD-CP00 upgrade procedures. When a
PZ-ME50 is mounted on a CPU, all software
upgrades are stored on this daughter board. If
the PZ-ME50 were to be removed from the CPU,
a software upgrade must be performed to bring
the CPU to the latest version.
UNIVERGE SV8100
Installing the SV8100 Blades