Door Box /External Page Relay Contacts
6.2.1
Connecting a Contact Relay Device to a Door Box/External Page
Relay
To connect a dry contact relay device to a Door Box/External Page
Relay:
To connect to the CD-CP00:
1.
Connect an RCA line from the CN8 or CN9 connector on the
CD-CP00 to the appropriate location on the extension cross-
connect block.
2.
Connect the two-conductor station cable from the
cross-connect block to the external relay.
3.
Install bridging clips as required.
OR
To connect to the PGD Adapter:
1.
Make sure the jumper in the PGD Adapter for the channel is set
correctly. (Refer to
on page
2.
If a line cord was not previously connected to the PGD Adapter,
complete Steps 3~6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD Adapter. For each module,
run one-pair 24 AWG station cable from the cross-connect
block to a modular jack. Ground the unused pair.
4.
Terminate the extension leads to GRN/RED of the modular
jack. Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1
connector on the PGD Adapter.
7.
Connect the two-conductor station cable from the CN5
connectors in the PGD Adapter to the external relay.
Figure 7-4 PGD Adapter Jumper Settings
7-4).