Figure 7-22 Nec Terminal Connection To An Ieee 802.3Af Poe Switch - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100

Figure 7-22 NEC Terminal Connection to an IEEE 802.3af PoE Switch

System Hardware Manual
3.
Connect the NEC VoIP telephone to the TEL connector on the
ILPA-R adapter with the LAN cable provided with the adapter.
If a customer-provided cable is used, the total length from
the switch to the telephone should be less than 328 feet.
The adapter can be positioned either closer to the
multiline terminal or switch – it does not matter.
4.
Connect a crossover LAN cable to the LAN connector on the
ILPA-R adapter. Plug the opposite end into the switch which is
to provide power to the telephone. Refer to
Terminal Connection to an IEEE 802.3af PoE
If a straight-through cable is used, NIC Auto Detection
must be enabled in Programs 10-12-05 (CD-CP00), 84-
05-02 (VOIPU) or 85-01-03 (SHUBU).
Issue 9.0
Figure 7-22 NEC
Switch.
7 - 31

Advertisement

Table of Contents
loading

Table of Contents