CHAPTER 5 MAINTENANCE AND INSPECTION
4.2 Scheduled Service Work
Perform the following when maintaining the area around the drum as part of scheduled
service work:
4.2.1 Work 1
a. Cleaning the side scraper assembly
b. Cleaning the toner receptacle
During the work, take care not
to rotate the magnet roller drive
assembly. Otherwise, waste
toner will drop from the cleaner
assembly.
1) Slide out the process unit. (See 5.8.1 in
Chapter 2.)
Be sure to place a protective
sheet over the fixing/feeder unit.
2) Take out the photosensitive drum.
3) Take out the cleaner blade assembly.
4) While keeping the magnet roller [1] and
the scraper [2] at the front, move the
build-up of waste toner with a piece of
paper [3] or the like toward the
feedscrew rear.
5-16
COPYRIGHT© 2001 CANON INC.
[3]
[1]
F05-402-01
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
[2]