E240
Main cause
The main controller PCB is faulty. The DC controller PCB is faulty. The
wiring is faulty (short circuit, open circuit).
Condition
0000 A communication fault exists between the CPUs of the main con-
E241
Main cause
The original orientation detection PCB is faulty. The wiring is faulty (short
circuit, open circuit). The reader controller PCB is faulty.
Condition
0000 The initial communication between the CPUs of the original orien-
0001 When the orientation of an original is detected, the result of detec-
0002 The result of detection of the last original is not communicated 5
E243
Main cause
The control panel CPU PCB is faulty. The main controller PCB is faulty.
Condition
0000 A communication fault exists between the CPUs of the control
E251
Main cause
The inverter cooling fan (FM9) is faulty. The wiring is faulty (short circuit,
open circuit). The read controller PCB is faulty.
Condition
0000 The lock signal (FM9LCK) arrives for 5 sec or more although the
E302
Main cause
The CCD/AP PCB is faulty. The wiring is faulty (short circuit, open cir-
cuit). The reader controller PCB is faulty.
Condition
0000 During shading operation, the reader controller PCB fails to end
COPYRIGHT© 2001 CANON INC.
troller PCB and the DC controller PCB.
tation detection PCB and the reader controller PCB fails.
tion is not communicated by the original orientation detection PCB
until the next original is read.
sec after the end of reading the last original.
panel CPU PCB and the main controller PCB.
inverter cooling fan (FM9) is being driven.
shading processing.
2000 2000 2000 2000