No.
Work
12 Clean the cleaner assembly:
• Side scraper
13 Clean the duplex assembly:
• Duplex horizontal registration
sensor
14 Clean the copyboard glass.
15 Make test copies.
16 Make sample copies.
17 Press the leakage breaker test
switch to make sure that it oper-
ates normally. Thereafter, turn
off the power switch, and shift
the lever to the ON side; then,
turn on the power switch.
Check to make sure that
the grounding is cor-
rect. Otherwise, pos-
sible leakage will not
turn on the leakage
breaker.
18 Put the sample copies into order,
and clean up the area around the
machine.
19 Record the last counter readings.
20 Fill out the Service Book, and
report to the person in charge.
COPYRIGHT© 2001 CANON INC.
CHAPTER 5 MAINTENANCE AND INSPECTION
With the power switch set to
ON and, in addition, the le-
ver [1] of the leakage breaker
in ON state, press the test
switch. If normal, the lever
should flip to the OFF side,
cutting the power. (Pay atten-
tion to its orientation when
replacing it.) If you have re-
placed the leakage breaker,
be sure to make this check.
Be user to describe the check
on the leakage breaker in the
Service Book.