j. Removing the Bi-centronics PCB
1) Remove the rear cover. (See 8.4.1.e.)
2) Remove the rear upper cover (2 screws),
left lower cover (2 screw), left upper
cover (9 screws), and upper left cover (3
screws).
3) Disconnect the 3 connectors [1].
4) Remove the screw [1], and detach the
harness fixing plate [2].
5) Remove the 2 screws [1], and detach the
positioning pin [2].
6) Remove the 5 screws [3], and detach the
Bi-centronics PCB unit [4].