The Dc Power Supply Fails To Operate. 1 - Canon iR105 Service Manual

Hide thumbs Also See for iR105:
Table of Contents

Advertisement

CHAPTER 6 TROUBLESHOOTING

4.1.72 The DC power supply fails to operate. 1

Control pane power switch-related items
1) Is the main power lamp ON?
YES: See "The DC power supply fails to operate. 2"
AC power supply
2) Is the rated voltage present between J28-1 and J28-5 and between
NO:
Wiring
3) Is the cable of the connector J1701-4 (overcurrent detection signal
NO:
Fuse (FU101)
4) Is the fuse (FU101) on the DC power supply PCB blown?
YES: Remove the cause, and replace the fuse.
Wiring, DC load, DC power supply PCB
5) Turn off the main power switch. When the main power switch is
YES: Turn off the power switch, and disconnect the following connectors
NO:
6-124
J28-2 and J28-7 on the DC power supply PCB?
See "AC power is absent."
1) on the relay PCB normal?
Correct it.
turned on in about 3 min, is the voltage between the following ter-
minals of the relay PCB normal?
Connector
J1704
J1705
J1706
However, the output voltages in the table are based on a tolerance
in AC input of ±10%.
of the relay PCB:
• J1711
• J1712
• J1714
• J1716
• J1718
Connect one of the disconnected connectors, and turn on the power
switch. Repeat this for all connectors to find the connector for
which the protective circuit goes ON. Then, check the wiring and
DC loads connected to the connector.
Replace the DC power supply PCB.
COPYRIGHT© 2001 CANON INC.
Pin No.
Output voltage
1
3
3.3V
1
3
5
1
2000 2000 2000 2000
Remarks
12V
+7%, -10%
±5%
+8V
±10%
-8V
±10%
15V
±10%
5V
±4%
CANON iR105 REV.0 JULY 2001