TEMP-TBL
Use it to select a fixing temperature.
Setting
0: 183°C
1: 193°C
2: 178°C
3: 173°C
4: 168°C
DRM-H-SW
Use it to set the night drum heater OFF mode.
Setting
0: night drum heater ON (default)
1: monitor ambient humidity every 2 hr; turn off drum heater if abso-
lute water content is 9 g or less
DEV-IDLR
Use it to set black band developing forced idle rotation mode used at time
of power-on.
Setting
0: execute black band developing idle rotation sequence at power-on if
2000 copies or more were made on previous day and, in addition, ab-
solute water content is 16 g or more (default)
1: execute black band developing idle rotation sequence at power-on at
all times
BK-BD-1
Use it to set black band monthly remedial mode (for January).
Setting
0: do not execute if absolute water content is less than 9 g
execute every 200 copies if absolute water content is 9 g or more (de-
fault)
1: execute black band sequence every 60 copies
2: execute black band sequence every 20 copies
3: execute black band sequence every 6 copies
BK-BD-2
Use it to set black band monthly remedial mode (for February).
Setting
Same as for January.
BK-BD-3
Use it to set black band monthly remedial mode (for March).
Setting
Same as for January.
BK-BD-4
Use it to set black band monthly remedial mode (for April).
Setting
Same as for January.