ERROR CODE
E717
Main cause
The wiring is faulty. (short circuit, open circuit). The copy data controller or
the NE controller is faulty. The main controller PCB is faulty.
Condition
0001 The copy data controller or the NE controller is out of order or the
Caution
You must clear the error in service mode
(COPIER>FUNCTION>CLEAR>ERR).
E719
Main cause
The wiring is faulty (short circuit, open circuit). The coin vendor is faulty.
The main controller PCB is faulty.
Condition
0002 The communication between coin vendor and controller PCB is
Caution
You must clear the error in service mode
(COPIER>FUNCTION>CLEAR>ERR).
E732
Main cause
The cable connector is not connected properly. The reader controller PCB is
faulty.
Condition
0001 The main controller PCB detects a fault in the communication be-
E733
Main cause
The connector is not connected properly. The DC controller PCB is faulty.
Condition
0000 The machine controller PCB detects a fault in the communication
E737
Main cause
The SDRAM is faulty. The main controller PCB is faulty.
Condition
0000 A fault exists in the SDRAM.
E-28
wiring has an open circuit.
disrupted.
tween rear controller PCB and main controller PCB.
between DC controller PCB and main controller PCB.