CHAPTER 6 TROUBLESHOOTING
10) Connect the cable [1] of the potential sensor checker electrode to the frame assembly
(GND) [2] of the machine.
Never bring the clip into contact with the sensor cover. Be sure to fit it fully
away from the sensor window.
11) Fit the door switch actuator in the door switch assembly.
12) Connect the power plug to the power outlet, and turn on the main power switch.
13) Execute the following in service mode: COPIER>FUNCTION>DPC>OFST.
14) Record the value of <OFST> on the service label.
15) Turn off the main power switch.
16) Disconnect the power plug from the power outlet.
17) Detach the potential sensor checker electrode.
18) Put back the potential sensor support plate.
19) Connect the power plug, and turn on the main power switch.
6-46
F06-207-05