• ADF (from E400 to E420)
E400
Main cause
The communication cable between ADF and copier is faulty. The ADF con-
troller PCB is faulty.
Condition
0000 While the ADF is in standby, the communication between ADF and
E402
Main cause
The belt motor (M2) inside the ADF is faulty. The belt motor clock sensor
(PI1) is faulty. The ADF controller PCB is faulty.
Condition
0000 The clock signal does not occur for 100 msec when the belt motor
E404
Main cause
The delivery motor (M5) is faulty. The delivery motor clock sensor (PI11)
is faulty. The ADF controller PCB is faulty.
Condition
0000 The clock signal does not occur for 200 msec when the delivery
E405
Main cause
The separation motor (M4) is faulty. The separation motor clock sensor
(PI2) is faulty. The ADF controller PCB is faulty.
Condition
0000 The clock signal does not occur for 200 msec when the separation
COPYRIGHT© 2001 CANON INC.
copier is interrupted for 5 sec or more. Or, when the ADF is in op-
eration, the communication between ADF and copier is disrupted
for 0.5 sec or more.
drive signal is generated.
motor drive signal is generated.
motor drive signal is generated.
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001