Canon iR105 Service Manual page 697

Hide thumbs Also See for iR105:
Table of Contents

Advertisement

ERROR CODE
E032
Main cause
The copy data controller or the NE controller is faulty. The main controller
PCB is faulty.
Condition
0000 The copy data controller or the NE controller are disconnected af-
E043
Main cause
The side paper deck main motor (M101) is faulty. The side deck driver PCB
is faulty. The DC controller PCB is faulty.
Condition
0000 The PLL lock signal (DMPLK) does not arrive for 2 sec or more
E051
Main cause
The horizontal registration sensor (PS18) is faulty. The horizontal registra-
tion motor (M15) is faulty. The DC controller PCB is faulty.
Condition
0001 Departure from home position is not detected within 5 sec during a
0002 Home position is not detected within 5 sec during a horizontal reg-
0003 The horizontal registration detection movement for the preceding
E065
Main cause
The primary charging assembly is faulty. The HV-DC PCB is faulty. The
wiring is faulty (short circuit, open circuit).
Condition
0000 An error (leakage) is detected in the high-voltage output to the pri-
E-6
ter they have once been connected.
after the side paper deck main motor drive signal has been gener-
ated.
horizontal registration home position search.
istration home position search.
sheet does not end within 5 sec at the start of a horizontal registra-
tion search during printing.
mary charging assembly.
COPYRIGHT© 2001 CANON INC.