E068 - Canon iR105 Service Manual

Hide thumbs Also See for iR105:
Table of Contents

Advertisement

CHAPTER 6 TROUBLESHOOTING

4.1.20 E068

Mounting
1) Is the transfer/separation charging assembly mounted firmly?
NO:
Connection
2) Are the following connectors on the HV-DC PCB and HV-AC PCB
NO:
Separation charging assembly
3) Disconnect the connector T1-S from the transformer assembly of
NO:
6-98
Mount it firmly.
and the screws connected and tightened firmly? (See F06-401-03.)
HV-DC PCB
• J722
• J722
• J722
• J734
Connect and tighten them firmly.
the HV-AC PCB, and execute copying. Is E068 indicated? (See F06-
401-04.)
Clean the separation charging assembly. If E068 still is indicated
when executing copying, replace the separation charging assembly.
COPYRIGHT© 2001 CANON INC.
HV-AC PCB
• J741
• J742
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001

Advertisement

Table of Contents
loading

Table of Contents