4.1.80 The pre-exposure lamp fails to go ON

Pre-exposure lamp PCB
1) Select the following in service mode: COPIER>I/O>IP. Does the
YES: Check the wiring from DC controller PCB to the pre-exposure
DC controller PCB, Pre-exposure lamp PCB
2) Set the meter range to 300 VDC. Does the voltage between J504-A1
NO:
YES: Check the wiring from the DC controller PCB to the pre-exposure

4.1.81 The scanning lamp fails to go ON

Connector
1) Make the following selections in service mode:
YES: The connector may have poor contact. Check the connector.
Lamp
2) Is the scanning lamp (LA1) mounted correctly?
NO:
Relay PCB
3) Measure the voltage of J1001-1 on the inverter PCB. Is it 38 V?
NO:
Inverter PCB, Reader controller PCB
4) Measure the voltage of J1109-B11 on the reader controller PCB.
YES: If the wiring is normal, replace the inverter PCB.
NO:
COPYRIGHT© 2001 CANON INC.
state of bit 0 at address P016 change from '0' to '1' when the Start
key is pressed?
lamp PCB; if normal, replace the pre-exposure lamp.
(+) on the DC controller PCB and GND change from 0 to 24 V
when the Start key is pressed?
Replace the DC controller PCB.
lamp PCB; if normal, replace the pre-exposure lamp PCB.
COPIER>FUNCTION>MISC-R>SCANLAMP. Does the scanning
lamp remain ON for 3 sec when the OK key is pressed?
Disconnect the power plug from the power outlet, and mount the
lamp correctly.
Check the AC line up to the relay PCB; if normal, replace the relay
PCB.
Does it change from 5 to 0 V when the control panel power switch is
tuned on?
If the wiring is normal, replace the DC controller PCB.