CHAPTER 2 NEW FUNCTIONS
b-2 Removing the No. 1 Mirror Case Flexible Cable
Do not disconnect the connector
(connected to the No. 1 mirror
base) of the flexible cable un-
less you are replacing the No. 1
mirror base. (Clean the mirror
without detaching the cable.)
1) Remove the right glass retainer. (2
screws)
2) Remove the copyboard.
3) Move the No. 1 mirror base [1] to the
center.
When moving the mirror base,
be sure not to touch the mirror
or the lamp or impose force to
avoid dirt or damage.
4) Peel off the Warning label [1] from the
flexible cable [2].
2-22
COPYRIGHT© 2001 CANON INC.
F02-209-20
[2]
F02-209-21
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
[1]