2.8 Potential Control System Conversion Table
Control
Primary
(V)
(µA)
3.00
1600
3.05
1590
3.10
1580
3.15
1570
3.20
1560
3.25
1550
3.30
1540
3.35
1530
3.40
1520
3.45
1510
3.50
1500
3.55
1490
3.60
1480
3.65
1470
3.70
1460
3.75
1450
3.80
1440
3.85
1430
3.90
1420
3.95
1410
4.00
1400
4.05
1390
4.10
1380
4.15
1370
4.20
1360
4.25
1350
4.30
1340
4.35
1330
4.40
1320
4.45
1310
4.50
1300
4.55
1290
4.60
1280
4.65
1270
4.70
1260
4.75
1250
4.80
1240
4.85
1230
4.90
1220
4.95
1210
COPYRIGHT© 2001 CANON INC.
Developing
bias (V)
0
3
7
11
15
18
22
26
30
33
37
41
45
48
52
56
60
63
67
71
75
78
82
86
90
93
97
101
105
108
112
116
119
123
127
131
134
138
142
146
T06-208-01
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
CHAPTER 6 TROUBLESHOOTING
Pre-transfer
Transfer
(µA)
+0
+2
+4
+6
+8
+10
+12
+14
+15
+17
+19
+21
+23
+25
+27
+29
+30
+32
+34
+36
+38
+40
+42
+44
+45
+47
+49
+51
+53
+55
+57
+59
+60
+62
+64
+66
+68
+70
+72
+74
Separation
(µA)
(µA)
+0
+0
-4
+5
-8
+10
-12
+15
-16
+20
-20
+25
-24
+30
-28
+35
-32
+40
-36
+45
-40
+50
-44
+55
-48
+60
-52
+65
-56
+70
-60
+75
-65
+80
-69
+85
-73
+90
-77
+95
-81
+100
-85
+105
-89
+110
-93
+115
-97
+120
-101
+125
-105
+130
-109
+135
-113
+140
-117
+145
-121
+150
-125
+155
-129
+160
-134
+165
-138
+170
-142
+175
-146
+180
-150
+185
-154
+190
-158
+195
6-53