7) Fit the potential sensor checker electrode (FY9-3041) [2] to the potential sensor [1].
When fitting the checker electrode to the potential sensor, be sure that the
magnet of the checker electrode will not come into contact with the poten-
tial sensor cover.
8) Connect the cable [1] of the potential sensor checker electrode to the frame (GND) [2]
of the machine.
Never bring the clip into contact with the sensor cover. Be sure to keep it
fully away from the sensor window.
COPYRIGHT© 2001 CANON INC.
[2]
F06-207-10
F06-207-11
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
CHAPTER 6 TROUBLESHOOTING
[1]
[2]
[1]
6-51