CHAPTER 2 NEW FUNCTIONS
4) Move the No. 1 mirror base [1] to
where the scanning lamp mirror inside
cover has been removed; then, remove
the 2 screws [2], and detach the anti-
reflection plate [3].
When moving the mirror base,
be sure not to touch the mirror
or the lamp or impose force on
them to avoid dirt or damage.
When mounting the anti-reflec-
tion plate, be sure to fit the plate
firmly in the cut-in ([2] at front,
[3] at rear) of the No. 1 mirror
base. Also, be sure that the con-
nector in step 5) is firmly to the
anti-reflection plate.
2-14
COPYRIGHT© 2001 CANON INC.
[3]
[1]
F02-209-03
[1]
F02-209-04
[3]
F02-209-05
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
[2]
[2]
[2]
[1]