Double Feeding Detection Pcb ( Reception ); Fixing Heat Discharge Fan - Canon imageRUNNER 7095 Service Manual

Hide thumbs Also See for imageRUNNER 7095:
Table of Contents

Advertisement

Chapter 10
4) Remove the fixing/feeding unit cover [1].
- 2 screws [2]
[2]
F-10-95
10.5.31.2 Removing the Double-Feed
Detection Unit (transmitting)
1) Remove the double-feed Detection PCB
(transmitting) [1].
- 2 connectors [2]
- 4 screws [3]
[2]
[3]
F-10-96
10.5.32 Double Feeding Detection PCB (
Reception )
10.5.32.1 Before Starting the Work
1) Remove the primary charging assembly cover.
2) Remove the process unit cover.
10-26
[1]
0011-8285
[1]
0011-8280
10.5.32.2 Removing the Double-Feed
Detection Unit (reception)
1) Remove the double-Feed Detection PCB
(reception) [1].
- 2 connectors [2]
- 4 screws [3]
[3]
[1]
F-10-97

10.5.33 Fixing Heat Discharge Fan

10.5.33.1 Removing the Fixing Heat
Discharge Fan (FM2)
1) Remove the rear cover.
2) Remove the 2 screws [1], and disconnect the
connector [2]; then, detach the fixing heat
discharge fan [3].
[1]
F-10-98
When mounting the fan, be sure that the direction
of air current is as indicated by the arrow.
0011-8286
[2]
[3]
[2]
0010-9597
[2]
[1]
[3]

Advertisement