Chapter 7
4) Remove the spring [1], and detach the
separation claw [2].
F-7-112
Points to Note When Mounting
When mounting the separation claw holder, be
sure that the separation claw holder spring is butt-
ed against the drum cleaner case. Further, check
to make sure that the rack of the separation claw
3 drive assembly is engaged with the groove in
the separation claw holder.
Separation claw holder
F-7-113

7.10.17 Potential Sensor

7.10.17.1 Removing the Potential Sensor
Unit
1) Open the front cover.
2) Remove the process unit.
3) Push in the fixing/feeding assembly.
4) Remove the cable guide [1].
- 1 screw [2]
5) Slide out the dust-blocking glass [3] to detach.
7-48
[1]
[2]
Rack
0010-8881
6) Remove the potential sensor unit [4].
- 1 connector [5]
- 1 screw [6]
[2]
[1]
[3]
F-7-114
It is rather difficult to slide out the potential sen-
sor unit in horizontal direction. As shown, push it
down before sliding it out to facilitate the work.
F-7-115
7) Remove the 2 screws [1], and detach the
potential sensor cover [2]; then, detach the

potential sensor [3].

[1]
[2]
F-7-116
Be sure to replace the potential sensor at the same
time as the potential controller PCB.
When mounting it, fit the protrusion on the rear of
the potential sensor stay in the hole of the side
plate found at the rear of the machine; then, match
it on the side plate found at the front to screw it in
place.