9.5.10 Fixing Cleaning Belt

9.5.10.1 Removing the Fixing Cleaning
Belt
1) Slide the fixing/feeding unit halfway out; then,
release the stoppers on both rails, and slide the
unit farther out.
2) Remove the pre-transfer charging assembly
cover, fixing feeding unit releasing lever, and
fixing roller knob.
3) Remove the screw [1], and detach the fixing
assembly upper cover [2].
[1]
F-9-51
4) Remove the two screws [3] used to secure the
fixing cleaning belt assembly, and open the top
of the fixing cleaning belt assembly upward.
[3]
F-9-52
0010-9534
[2]
[3]
5) While pushing the cleaning belt feeding roller
[4] and the take-up roller [5] toward the rear,
detach the cleaning belt [6].
[5]
F-9-53
When cleaning the silicone oil pan, be sure to re-
move the silicone oil collecting in the oil pan [7]
found under the cleaning belt feeding roller.
F-9-54
Chapter 9
[6]
[4]
[7]
9-19