9.5.3.2 Adjusting the Lower Roller
Pressure (nip)
The nip width must be as indicated in figure; if
not, adjust it using the pressure adjusting nut.
Feed
direction
F-9-30
a and c are points 10 mm from both edges of pa-
per.
Dimension
Measure with upper and lower
rollers fully heated
b
200 V: 9.0 -/+ 0.5 mm, 208/230 V:
10.0 -/+ 0.5 mm
| a-c |
0.5 mm or less
a.
Generating
Output
Measurement
Wait for 15 min after the copier ends its warm-up
period; make 20 A4 copies, and measure the nip.
1) Place A3 copy paper in the manual feed tray.
2) Make the following selections in service mode
to generate output:
COPIER > FUNCTION > FIXING > NIP-
CHK.
The A3 paper will be picked up, and a copy like
the one shown in figure will be delivered.
c
b
Middle
of paper
a
T-9-2
for
Nip
Width

9.5.4 External Delivery Roller

9.5.4.1 Removing the External Delivery
0010-9395
Roller
1) Remove the fixing assembly.
2) Remove the 3 screws [1]; then, while opening
the upper delivery assembly [2], remove the
delivery roller guide [3].
3) Remove the E-ring [1] at the front, slide the
bearing [2] in the direction of the gear.
4) Remove the E-ring [1], and slide the bearing
[2] toward the rear; then, detach the external
delivery roller assembly [3].
[3]
[2]
[1]
F-9-31
[2]
[1]
F-9-32
[1]
[2]
F-9-33
Chapter 9
0010-9397
[3]
9-15

Advertisement