Chapter 5

5.4.3 Standard White Plate

5.4.3.1 Removing the Standard White
Plate <iR7105/7095>
1) Remove the 2 small covers [1]. (Use a
precision screwdriver to release the claw.)
[1]
F-5-59
2) Remove the standard white plate [1].
- 4 screws [2]
[2]
[1]
[2]
F-5-60
5.4.3.2 When Replacing Components of
the Scanning System <iR7105/7095>
<Components>
CCD unit, copyboard glass, scanning lamp,
standard white plate, inverter PCB
<Procedure>
Execute the following service mode item:
1) COPIER> FUNCTION> CCD> CCD-ADJ
(shading correction based on the standard white
plate)
5-26

5.4.4 Scanning Lamp

5.4.4.1 Before Starting the Work <iR7105/
7095>
0011-8033
1) Remove the copyboard glass.
2) Remove the hopper upper cover.
3) Remove the primary charging assembly cover.
4) Remove the process unit cover.
5) Remove the upper inside cover.
6) Remove the upper front cover unit [1].
- 3 screws [2]
7) Remove the lower left cover.
8) Remove the upper left cover.
9) Remove the reader front cover [1].
- 2 screws [2]
- 2 magnets [3]
[3]
0011-8732
10) Remove the reader left cover [1].
- 4 screws [2]
[1]
[2]
F-5-61
[2]
[3]
[1]
F-5-62
[2]
[2]
F-5-63
0011-8535
[1]