Chapter 17
<HV-SP>
Sub item
Notes:
At times, the indicated value for the following items may differ before and after input (maximum of +/-3).
The fact has to do with the way indicated values are computed, and will not affect the operation of the
machine.
SP-N1
Use it to enter the output adjustment value of the separation charging current. (plain paper,
simplex mode; or, 1st side of double-sided print)
range: 0 to 800
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
SP-N2
Use it to enter the output adjustment value of the separation charging current. (plain paper,
2nd side of double-sided print)
range: 0 to 800
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
HVT-SP
Use it to enter the offset value of the separation high-voltage output for the high-voltage unit.
range: -100 to 100
Be sure to enter the value indicated on the label attached to the new unit if you have replace
the high-voltage unit.
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
D-HV-SP
Use it to enter the offset value of the separation high-voltage output for the DC controller
PCB.
range: -100 to 100
Be sure to enter the value indicated on the label attached to the new PCB if you have replaced
the DC controller PCB.
Be sure to enter the value indicated on the service label if you have initialized the RAM on
the DC controller PCB.
<FEED-ADJ>
Sub item
REGIST Use it to adjust the timing at which the registration roller clutch goes on.
A higher setting will delay the timing at which the registration roller clutch goes on, thus
decreasing the lead edge margin.
range: -100 to 100 (unit: 0.1 mm)
ADJ-
Use it to adjust the horizontal registration for re-pickup.
REFE
Increase the value if the image is displaced to the front.
range: -100 to 100 (unit: 01 mm)
Be sure to enter the value indicated on the service label if you have replaced the DC controller
PCB or initialized the RAM.
17-44
T-17-26
COPIER > ADJUST > HV-SP
Description
T-17-27
COPIER > ADJUST > FEED-ADJ
Description
Level
1
1
1
1
Level
1
1