Separation Roller - Canon imageRUNNER 7095 Service Manual

Hide thumbs Also See for imageRUNNER 7095:
Table of Contents

Advertisement

Chapter 8
8.11.22.14 Removing the Horizontal
Registration Sensor
1) Remove the duplexing unit from the main
body.
2) Remove the front cover.
3) Disconnect the connector [1], and remove the
three screws [2].
F-8-141
4) Remove the screw [3], and detach the
duplexing unit right fixing assembly [4]; then,
remove the two screws [5] at the rear, and
detach the right grip plate [6].
[6]
[5]
[4]
F-8-142
When mounting the right grip plate, be sure that
the boss on the grip plate is in the hole of the side
plate.
5) Remove the screw [7], and detach the
horizontal registration sensor [8].
[8]
F-8-143
8-50
[2]
[1]
[2]
[3]
[7]

8.11.23 Separation Roller

8.11.23.1 Removing the Separation Roller
0010-9377
1) Remove the two mounting screws [1], and
remove the feeding guide plate [2]; then, detach
the open/close guide [3]. (Skip this step for the
pickup assembly of the front deck left.)
2) Remove the two mounting screws [4], and
remove the separation roller assembly [5] from
the joint. (If for the pickup assembly of the
front deck left, remove one screw.)
3) Detach the separation roller [6] from the
separation roller shaft mount.
[6]
Initially, the urethane sponge of the part is pink,
and changes over time (accelerated if exposed to
light).
Its tone will change from pink to orange and to
yellow; it is a general characteristic of urethane
sponge, and no physical deterioration (in per-
formance) exists because of changes in color, and
the part is not identified by color.
Urethane sponge pieces
[3]
[1]
[2]
[1]
F-8-144
[4]
[4]
[5]
F-8-145
F-8-146
F-8-147
0010-9378

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner 7105Imagerunner 7086

Table of Contents