3
3.1 General Specifications
- 2
When mounting MELSECNET/H communication unit (GT15-J71LP23-25, GT15-J71BR13) or CC-Link
communication unit (GT15-J61BT13), the operating ambient temperature must be reduced 5°C against the
maximum values described in general specifications.
When using the MELSECNET/10 communication unit (GT15-75J71LP23-Z, GT15-75J71BR13-Z) or CC-Link
communication unit (GT15-75J61BT13-Z), refer to the manual of the communication unit you use. (Differs with
the specification of GOT.)
Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to
observe this instruction may cause a malfunction.
When an air purge is made inside the control panel by adding pressure, there may be a clearance between the
surface sheet and the screen making it difficult to use the touch panel, or the sheet may come off.
This indicates the section of the power supply to which the equipment is assumed to be connected between the
public electrical power distribution network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
This index indicates the degree to which conductive material is generated in the environment where the
equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to
condensation.
For the STN LCD model, the wet-bulb temperature must be 39°C or less.