11.3 Operation settings

11.3.1 Operation setting functions

Setting regarding GOT operation can be set.
The items which can be set are described below. If touch the each item part, the respective setting becomes
possible.
Function
Buzzer volume setting
Window move buzzer volume setting
Security setting screen change
Utility call key screen change
Key sensitivity setting
Touch panel calibration
Touch detection mode
SoftGOT-GOT link function setting
*1 Relation between the [Key sensitivity] setting and [Key reaction speed]
The larger the set value in [Key sensitivity] is, the shorter the time taken from touching the touch panel
until the GOT responds becomes.
E.g. decrease the value set for [Key sensitivity] when double-touch is made when touching the GOT
screen only once. (Decrease the reaction speed.)
The relation between the [Key sensitivity] setting and [Key reaction speed] is as follows.
Quick response
[Key sensitivity] setting
[Key reaction speed]
- 20ms-
Buzzer volume setting can be changed.
Whether turn ON/OFF buzzer when move window
can be selected.
Security level change screen can be displayed.
11.4 Security Level Change
Utility call key setting screen can be displayed.
11.5 Utility Call Key Setting
The touch panel sensitivity when touching the GOT
screen can be set.
E.g. a setting can be changed when double-touch is
made when touching the GOT screen only once. (For
preventing chattering)
Touch panel reading error can be corrected.
11.6 Adjusting the Touch Panel Position
(Touch panel calibration Setting)
For the GT1595-X, whether to reduce incorrect
inputs (responses of parts other than the touched
part) when more than 2 points are touched
simultaneously on the GOT or to prioritize response
can be selected.
The authorization of the SoftGOT-GOT link function
can be set, and the exclusive authorization can be
obtained or released.
11.7 SoftGOT-GOT Link Function Setting
8
7
6
0ms
- 10ms
(Standard)
Description
5
4
3
+ 10ms
+ 20ms
+ 40ms
11.3 Operation settings
11.3.1 Operation setting functions
Setting range
OFF/SHORT/LONG
<At factory shipment:
SHORT>
ON/OFF
<At factory shipment:
ON>
*1
1 to 8
Continuous key input/
Avoid input error
<Default: Continuous
key input>
Slow response
2
1
+ 80ms
+ 120ms
11
- 14
9
10
11
12
13
14
15
16