Error
Error message
code
Recipe device points too
570
large.
Capacity shortage of user
571
memory (RAM)
Abnormal Advanced
581
recipe file
Cannot generate
582
Advanced recipe file.
Unable to save device
583
value to Advanced recipe
file.
Advance recipe file save
584
error
Advanced recipe file
585
upload error
Specified Advanced
586
recipe number does not
exist.
Specified record number
587
does not exist.
Cannot save recipe data
588
to read only record.
Recipe device save error.
589
Recipe file does not exist.
Recipe device upload
590
error. Recipe device value
does not exist.
Advanced Recipe error.
591
Check recipe data.
Action
The number of the set points of the recipe device exceeds the
specified range.
Put the number of the set points of the recipe device within
the specified range.
There is no empty area/space in D drive.
Format the D drive in the memory to secure free area.
Advanced Recipe cannot be executed for advanced recipe
file with incorrect contents. Delete the advanced recipe file
from the memory card.
Cannot generate advanced recipe file. Confirm the following
and execute recipe processing again.
1. Confirm whether the memory card is installed.
2. Confirm whether the CF card access switch of the GOT is
ON.
3. Confirm the available memory of the memory card.
Unable to save device value to advanced recipe file.
1. Confirm the write-protection of memory card.
2. Confirm whether the attribute of saving file is for reading
only.
An error has occurred during the advanced recipe file writing.
Do not pull the memory card out while the Advanced Recipe
is operating.
An error has occurred during the advanced recipe file reading.
Do not pull the memory card out while the Advanced Recipe
is operating.
The advanced recipe of non-existing number is about to be
executed.
Execute advanced recipe of existing number.
The advanced record of non-existing number is about to be
executed.
Execute record of existing number.
Saving recipe is about to be executed to the record of which
recipe device value cannot be edited.
Make the recipe device value of the record editable with
Advanced Recipe Setting of GT Designer3 or GT Designer2
or specify the record of which recipe device value can be
edited.
Saving recipe is about to be executed to the advanced recipe
setting that is set for not using file.
Specify the advanced recipe setting that uses file.
Loading recipe is about to be executed to the record of which
recipe device value is not set.
Specify the record of which recipe device value is set.
The advanced recipe setting is not correct.
Confirm the advanced recipe setting of the project data and
download it to the GOT again.
20.3 ERROR MESSAGE AND SYSTEM ALARM