Mitsubishi GOT1000 GT15 User Manual page 439

Graphic operation terminal
Hide thumbs Also See for GOT1000 GT15:
Table of Contents

Advertisement

No.
Item
color*
PARAM.ERR
Red
F LOOP ERR
Red
SD
Green
RD
Green
TOKEN PASS
Green
DATA LINK
Green
(2)
GOT R/W
Green
R LOOP ERR
Red
*: For monochrome display, it is displayed as
(2) Loop information
Displays the loop status of the CC-Link IE Controller Network communication unit
No.
Item
IN: Loop Sts.
IN: LoopBK Sta
IN: LoopBK factor
(3)
OUT: Loop Sts.
OUT: LoopBK Sta
OUT: LoopBK factor
LED
Lit
Parameter error
IN-side error
Sending data
Receiving data
Baton pass being executed
Data link being executed
(Cyclic transmission exe-
cuted)
Offline, or hardware test,
self-loopback test, internal
self-loopback test or
station-to-station test being
executed
OUT-side error
(lit) or
Displays the IN-side connection status of the host station. (Normal/Rev
connect)
Displays the station No. of the IN-side loopback station.
(No loopback station: ---, value: 1 to 120)
Displays the cause of the loopback. (No LoopBK Sta./OUT: cable
disconnection/OUT: connecting a line/OUT: wrong cable connection)
Displays the OUT-side connection status of the host station. (Normal/Rev
connect)
Displays the station No. of the OUT-side loopback station.
(No loopback station: ---, value: 1 to 120)
Displays the cause of the loopback. (No LoopBK Sta./IN: cable
disconnection/IN: connecting a line/IN: wrong cable connection)
14.8.3 Display example of the NETWK unit status display
Not lit
No parameter error
No IN-side error
Not sending data
Not receiving data
Baton pass not executed
Data link being executed
Data link not executed
(Cyclic transmission stopped)
Online or circuit test being
executed
No OUT-side error
(not lit).
Description
14.8 NETWK Unit Status Display
9
Blink
10
11
.
12
13
14
15
16
14
- 27