Mitsubishi 3000GT Service Manual page 1251

Chassis and body
Hide thumbs Also See for 3000GT:
Table of Contents

Advertisement

HEATERS AND MANUAL
AIR CONDITIONING
-Heater Control Assembly
INSTALLATION SERVICE POINTS
Connect the temperature control wire to the blend air damper
lever by following the steps below.
(1) Move the temperature control lever to the rightmost
position. ("HOT position)
(2) With the blend air damper lever pressed completely
downward in the direction indicated by the arrow, connect
the inner cable of the temperature control wire to the
end of the blend air damper lever, and then secure the
outer cable: by using a clip.
INSTALLATION
Connect the mode selection control wire to the mode selection
damper lever by following the steps below.
(1) Move the mode selection lever to the defroster position.
(2) With the mode selection damper lever pressed' inward
in the direction indicated by the arrow, connect the inner
cable of the mode selection control wire to the end of
the mode selection lever, and then secure the outer cable
by using a clip.
Connect the air selection control wire to the air selection
damper lever by following the steps below.
(1) Move the air selection control lever to the recirculation
position.
(2) Set the air selection damper lever as it contacts stopper.
(3) Connect the inner cable of the air selection control wire
to the end of the air selection lever,
the outer cable by using a clip.
INSPECTION
BLOWER SWITCH CHECK
Operate the switch, and check the continuity between the
terminals.
Switch position
OFF
I
and
then secure
Terminal No.
5
3
6
2
7
8
1
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

1992 3000gt1993 3000gt1994 3000gt1996 3000gt3000gt 19923000gt 1993 ... Show all

Table of Contents