Sign In
Upload
Manuals
Brands
Mitsubishi Manuals
Controller
MELSEC-F FX3U-4AD
Mitsubishi MELSEC-F FX3U-4AD Manuals
Manuals and User Guides for Mitsubishi MELSEC-F FX3U-4AD. We have
3
Mitsubishi MELSEC-F FX3U-4AD manuals available for free PDF download: User Manual, Installation Manual
Mitsubishi MELSEC-F FX3U-4AD User Manual (466 pages)
FX3G SERIES FX3U SERIES FX3UC SERIES
Brand:
Mitsubishi
| Category:
Controller
| Size: 7.56 MB
Table of Contents
Table of Contents
7
Safety Precautions
3
Table of Contents
7
-4Ad-Tc-Adp (4-Channel Thermocouple Data Input)
20
Introduction
23
Common Items
23
Outline and Features of Analog Control
23
Analog Input Control
24
Analog Output Control
25
Temperature Sensor Input Control
26
Description of Analog Products
27
Types of Analog Products
27
Expansion Board
27
Special Adapter
28
Special Function Block
30
2.2 List of Analog Product Models
31
Special Adapter
31
Special Function Block
32
System Configuration Drawings of Analog Products
34
FX 3U Series PLC
34
Connection of Special Adapters
36
FX 3UC Series PLC
36
Connection of Special Function Blocks
38
FX 3G Series PLC
40
Connection of Expansion Boards, Special Adapters
40
Connection of Special Function Blocks
42
Comparison of Performance Specifications
43
Analog Input
43
Fx 3U -4Ad-Adp
43
Fx 2N -2Ad
44
Fx 3U -4Ad
45
Fx 2N -4Ad
46
Fx 3Uc -4Ad
47
Fx 2Nc -4Ad
48
Fx 2N -8Ad
49
Fx3G-2Ad-Bd
50
Analog Output
51
Fx 3U -4Da-Adp
51
Fx 2N -2Da
52
Fx 3U -4Da
53
Fx 2N -4Da
54
Fx 2Nc -4Da
55
Fx3G-1Da-Bd
56
Mixed Analog Input/Output
57
Fx 2N -5A
57
Fx 0N -3A
59
Temperature Sensor Input
60
Fx 3G /Fx
60
Fx 3U -4Ad-Pt-Adp
60
Fx 3U -4Ad-Ptw-Adp
60
Fx 3U -4Ad-Tc-Adp
60
Fx3U-4Ad-Pnk-Adp
60
Fx 2N -4Ad-Pt
64
Fx 2N -4Ad-Tc
65
Fx 2N -8Ad
66
Fx 2N -2Lc
67
Manual Introduction (Types, Contents, and Obtainment
68
5.1 How to Use the Manuals
68
5.2 Description of Related Manuals
69
Analog Control Manuals
69
Manuals Related to the FX /FX /FX 3UC Series PLC Main Unit
69
Manuals of Analog Units
71
Generic Names and Abbreviations in this Manual
73
Fx 3G /Fx
74
Fx 3U Fx 3Uc
79
Outline
79
Outline of Functions
79
Setup Procedure before Starting Operation
80
Connectable PLC and Version Numbers
81
Version Number of Compatible Programming Tools
82
Specifications
83
Generic Specifications
83
Power Supply Specifications
84
Performance Specifications
84
Input Mode (Characteristics) BFM #0
85
Wiring
87
Terminal Layout
88
Cable and Terminal Tightening Torque
89
Power Cable (FX 3UC -4AD
89
Cable (FX -4AD
90
Cable (FX 3UC -4AD
90
Examples of Power Supply Circuit
91
Fx 3U -4Ad
91
Cautions Regarding Connection of Power Cables
92
Fx 3Uc -4Ad
92
Analog Input Line
93
Grounding
94
Buffer Memory (BFM)
97
Buffer Memory Reading/Writing Method
99
Buffer Memory List (BFM)
100
Buffer Memory Details
104
BFM #28: Over-Scale Status
113
BFM #29: Error Status
114
BFM #30: Model Code
115
BFM #61 to #64: Addition Data
116
BFM #71 to #74: Lower Limit Error Setting / BFM #81 to #84: Upper Limit Error Setting
117
BFM #91 to #94: Abrupt Change Detection Value Setting
118
BFM #99: Clearance of Upper/Lower Limit Error Data and Abrupt Change Detection Data
119
BFM #109: Minimum Peak Value Resetting / BFM #119: Maximum Peak Value Resetting
120
BFM #126: Upper/Lower Error Status Data Automatic Transfer-To Data Register Specification
121
BFM #127: Abrupt Change Detection Status Data Automatic Transfer-To Data Register Specification
122
BFM #128: Over-Scale Status Data Automatic Transfer-To Data Register Specification
123
BFM #197: Selection of Cyclic Data Update Function (Function for Data History)
124
BFM #199: Data History Resetting/Stoppage
125
BFM #200 to #6999: Data History
126
Changing Input Characteristics
127
Examples of Practical Programs
130
Program that Uses Convenient Functions
132
Program that Uses Data History Function
135
Initialization Program for 4AD (Factory Default)
138
Troubleshooting
139
Error Status Check
140
AD Initialization and Test Program
141
Outline
145
Outline of Functions
145
Compatible Programming Tool Version Number
146
Setup Procedure before Starting Operation
146
Connectable Plcs and Version Number
147
Generic Specifications
148
D/A Conversion Time
149
Performance Specifications
149
Power Supply Specifications
149
A/D Conversion Time
150
Wiring
152
Terminal Layout
153
3.2 Applicable Cables and Terminal Tightening Torque
154
Power Supply Line
155
Analog Input Line
156
Grounding
156
Fx -4Ad
157
Programming
157
Programming
158
List of Special Devices
159
Fx 3Uc -4Ad
160
Switching of Input Mode
160
Input Data
161
Averaging Time
162
Error Status
163
Averaging Time
164
Model Code
165
Basic Program Example
166
Basic Program Example
167
Changing of Input Characteristics
168
Troubleshooting
171
Wiring Check
171
Program Check
172
Special Device Check
172
Error Status Check
173
Fx 3G /Fx
174
Fx 3G
175
Outline
177
Outline of Functions
177
Compatible Programming Tool Version Number
178
Setup Procedure before Starting Operation
178
Connectable Plcs and Version Number
179
Grounding
180
Specifications
180
Generic Specifications
180
Analog Input
181
Analog Input Procedures
181
Performance Specifications
181
A/D Conversion Time
182
Wiring
183
Terminal Layout
184
Applicable Cables and Terminal Tightening Torque
185
Analog Input Line
186
Grounding
186
Programming
187
Error Status
188
List of Special Devices
188
Model Code = 3
188
Input Data
189
Averaging Time
190
Error Status
191
Model Code
193
Changing of Input Characteristics
194
Troubleshooting
195
Checking Installation
195
PLC Version Number Check
195
Special Device Check
195
Wiring Check
195
Program Check
196
Outline
201
Setup Procedure before Starting Operation
202
Connectable Plcs and Version Numbers
203
Specifications
204
Power Supply Specifications
205
Output Mode (Characteristics) BFM #0
206
Wiring
207
Terminal Layout
208
Wiring to Power Supply Terminals
209
Analog Output Wiring
210
Analog Output
211
Buffer Memory (BFM
213
Assignment of Unit Numbers and Outline of Buffer Memory
213
Buffer Memory Reading/Writing Method
214
Buffer Memory Direct Specification (FX 3U , FX 3UC PLC Only
215
FROM/TO Instruction (FX , FX , FX 3UC PLC
215
Buffer Memory List (BFM
216
Buffer Memory Details
216
Buffer Memory Details
219
BFM #1 to #4: Output Data
220
BFM #6: Output Status
221
BFM #9: Offset/Gain Setting Value Write Command
222
BFM #10 to #13: Offset Data/Bfm #14 to #17: Gain Data
223
BFM #19: Data Change Prohibition of Setting Change
224
BFM #20: Initialization Function (Resetting to Factory Default Status
225
BFM #29: Error Status
226
BFM #30: Model Code
227
BFM #38: Upper/Lower Limit Function Setting
228
BFM #39: Upper/Lower Limit Function Status
229
BFM #41 to #44: Lower Limit Values of Upper/Lower Limit Function BFM #45 to #48: Upper Limit Values of Upper/Lower Limit Function
230
Only in Voltage Output Mode)/Bfm #51 to #54: Load Resistance Values
231
BFM #60: Status Automatic Transfer Function Setting
232
BFM #61: Error Status Data Automatic Transfer-To Data Register Specification
233
BFM #62: Upper/Lower Limit Function Status Data Automatic Transfer-To Data Register Specification
234
BFM #63: Specification of Data Register for Automatic Transfer at Disconnection Detection
235
Table Output Function
236
Preparation of Data Table
237
Procedures for Transferring Data Table to Buffer Memory
242
Procedures for Executing Table Output Function
246
Details of Table Output Error
248
Examples Uses of Table Output Function
250
Changing Output Characteristic
251
Examples of Practical Programs
254
Example of Program Using Useful Functions
255
Example of Program for Table Output Operation (Pattern Output Operation)
258
Troubleshooting
262
Error Status Check
263
FX 3U -4DA Initialization and Test Program
264
Outline
267
Setup Procedure before Starting Operation
268
Connectable Plcs and Version Numbers
269
Specifications
270
Power Supply Specifications
271
Wiring
274
Terminal Layout
275
Applicable Cables and Terminal Tightening Torque
276
Power Supply Line
277
Programming
279
List of Special Devices
281
Error Status
285
Model Code
287
Troubleshooting
290
Program Check
291
Outline
295
Setup Procedure before Starting Operation
296
Connectable Plcs and Version Numbers
297
Specifications
298
Performance Specifications
299
D/A Conversion Time
300
Wiring
301
Terminal Layout
302
Applicable Cables and Terminal Tightening Torque
303
Analog Output Line
304
Programming
305
List of Special Devices
306
Output Holding Function Cancellation Setting
307
Error Status
308
Basic Program Example
309
Changing of Output Characteristics
310
Troubleshooting
311
Program Check
312
Temperature Measurement
315
Selection of the Platinum Resistance Thermometer Sensor
326
Outline
371
Setup Procedure before Starting Operation
372
Connectable PLC and Its Version Number
373
Specifications
374
Performance Specifications
375
A/D Conversion Time
376
Temperature Measurement
377
Wiring
378
Terminal Layout
379
Applicable Cables and Terminal Tightening Torque
380
Power Supply Line
381
Wiring of the Resistance Thermomester Sensor
382
Caution Regarding Wiring
383
Programming
384
List of Special Devices
386
Selection of Temperature Unit
387
Temperature Measurement
389
Averaging Time
390
Error Status
391
Model Code
394
Basic Program Example
395
Troubleshooting
397
Program Check
398
Selection of the Thermocouple
414
Wiring of the Thermocouple Type J
415
Selection of Type K or J
420
PID Instruction (FNC
433
Basic Operation Expressions in PID Instruction (Reference)
436
Explanation of Function and Operation
437
Relationship between Parameter Setting and Auto-Tuning
438
Limit Cycle Method
461
Error Codes
462
Advertisement
Mitsubishi MELSEC-F FX3U-4AD User Manual (242 pages)
Programmable Controllers
Brand:
Mitsubishi
| Category:
Controller
| Size: 5.35 MB
Table of Contents
Safety Precautions
3
Table of Contents
7
Common Items
17
Introduction
17
Outline and Features of Analog Control
17
Analog Input Control
18
Analog Output Control
18
FX 3U -4AD-ADP (4-Channel Analog Input)
18
Temperature Sensor Input Control
19
Description of Analog Products
20
Various Types of Analog Products
20
Special Adapter
20
Special Function Block
21
List of Analog Product Models
22
Special Adapter
22
Special Function Block
23
System Configuration Drawings of Analog Products
25
FX 3U Series PLC
25
Connection of Special Adapters
25
Connection of Special Function Blocks
26
FX 3UC Series PLC
27
Connection of Special Adapters
27
Connection of Special Function Blocks
28
Comparison of Performance Specifications
29
Analog Input
29
Fx 3U -4Ad-Adp
29
Fx 3Uc -4Ad
30
Fx 2Nc -4Ad
31
Fx 2N -8Ad
32
Fx 2N -4Ad
33
Fx 2N -2Ad
34
Analog Output
35
Fx 3U -4Da-Adp
35
Fx 2Nc -4Da
36
Fx 2N -4Da
37
Fx 2N -2Da
38
Analog Input/Output Mixture
39
Fx 2N -5A
39
Fx 0N -3A
41
Temperature Sensor Input
42
Fx 3U -4Ad-Pt-Adp
42
Fx 3U -4Ad-Tc-Adp
43
Fx 2N -4Ad-Pt
44
Fx 2N -4Ad-Tc
45
Fx 2N -8Ad
46
Fx 2N -2Lc
47
Manual Introduction (Types, Contents, and Obtainment
48
How to Use Various Manuals
48
Description of Related Manuals
49
Analog Control Manuals
49
Manuals Related to FX /FX 3UC Series PLC Main Unit
49
Manuals of Analog Units
50
Generic Names and Abbreviations in this Manual
52
FX 3UC -4AD (4-Channel Analog Input)
55
Outline
57
Outline of Functions
57
Setup Procedure before Starting Operation
58
Connectable PLC and Its Version Number
59
Version Number of Compatible Programming Tool
59
Specifications
60
Generic Specifications
60
Power Supply Specifications
60
Performance Specifications
61
Input Mode (Characteristics) BFM #0
62
Wiring
64
Terminal Arrangement
65
Power Supply Line
66
Connection of Power Cable to Power Connector
66
Example of Power Supply Circuit
67
Cautions Regarding Connection of Power Cables
67
Cable Connection to Input Terminal and Tightening Torque
68
Analog Input Line
69
Grounding
69
Analog Data Reading
70
Procedure for Reading out of Analog Data
70
Buffer Memory (BFM
72
Assignment of Unit Numbers and Outline of Buffer Memory
72
Buffer Memory Reading/Writing Method
73
Buffer Memory Direct Specification
73
FROM/TO Instruction (Conventional Method
73
List of Buffer Memories (BFM
75
Details of Buffer Memories
79
BFM #0: Input Mode Specification
79
BFM #2 to #5: Number of Averaging Time
80
BFM #6 to #9: Digital Filter Setting
81
BFM #10 to #13: Channel Data
82
Number of Averaging Time
82
BFM #19: Data Change Prohibit
83
BFM #20: Initialization Function (Resetting to Factory Default Status
83
BFM #21: Input Characteristics Writing
83
BFM #22: Convenient Function Setting
84
Error Status
84
BFM #26: Upper/Lower Limit Error Status
86
5.4.10 BFM #27: Abrupt Change Detection Status
87
5.4.11 BFM #28: Over-Scale Status
88
5.4.12 BFM #29: Error Status
89
5.4.13 BFM #30: Model Code
90
5.4.14 BFM #41 to #44: Offset Data / BFM #51 to #54: Gain Data
90
5.4.15 BFM #61 to #64: Addition Data
91
5.4.16 BFM #71 to #74: Lower Limit Error Setting / BFM #81 to #84: Upper Limit Error Setting
92
5.4.17 BFM #91 to #94: Abrupt Change Detection Value Setting
93
5.4.18 BFM #99: Clearance of Upper/Lower Limit Error Data and Abrupt Change Detection Data
94
5.4.19 BFM #101 to #104: Minimum Peak Value / BFM #111 to #114: Maximum Peak Value
94
BFM #109: Minimum Peak Value Resetting / BFM #119: Maximum Peak Value Resetting
95
5.4.21 BFM #125: Peak Value Automatic Transfer to First Data Register Specification
95
BFM #126: Upper/Lower Error Status Data Automatic Transfer-To Data Register Specification
96
BFM #127: Abrupt Change Detection Status Data Automatic Transfer-To Data Register Specification
97
5.4.24 BFM #128: Over-Scale Status Data Automatic Transfer-To Data Register Specification
98
5.4.25 BFM #129: Error Status Data Automatic Transfer-To Data Register Specification
98
BFM #197: Selection of Cyclic Data Update Function (Function for Data History
99
5.4.27 BFM #198: Data History Sampling Time Setting
99
5.4.28 BFM #199: Data History Resetting/Stoppage
100
5.4.29 BFM #200 to #6999: Data History
101
Changing of Input Characteristics
102
Changing Input Characteristics
102
Procedure for Changing Input Characteristics
102
Examples of Practical Programs
105
Program that Uses Number of Averaging Time
105
Program that Uses Convenient Functions
106
Program that Uses Data History Function
108
Initialize Program for 4AD (Factory Default
110
Troubleshooting
111
PLC Version Number Check
111
Wiring Check
111
Program Check
111
Error Status Check
112
4AD Initialization and Test Program
113
Fx 3U
115
Outline
117
Outline of Functions
117
Setup Procedure before Starting Operation
118
Connectable PLC and Its Version Number
119
Version Number of Compatible Programming Tool
119
Specifications
120
Generic Specifications
120
Power Supply Specifications
121
Performance Specifications
121
D/A Conversion Time
121
Wiring
123
Terminal Layout
124
Applicable Cable and Terminal Tightening Torque
125
Power Supply Line
126
To Connect to the FX Series PLC
126
To Connect to the FX 3UC Series PLC
126
Analog Output Line
152
Grounding
152
Programming
153
Writing of D/A Conversion Data
153
List of Special Devices
154
Switching of Output Mode
154
Output Holding Function Cancellation Setting
155
Output Setting Data
155
Error Status
156
Model Code
157
Example of Basic Program
157
Changing of Output Characteristics
158
Example: Changing of Voltage Output Characteristics
158
Troubleshooting
159
PLC Version Number Check
159
Wiring Check
159
Special Device Check
159
Program Check
160
Error Status Check
160
Outline
163
Outline of Functions
163
Setup Procedure before Starting Operation
164
Connectable PLC and Its Version Number
165
Version Number of Compatible Programming Tool
165
Specifications
166
Generic Specifications
166
Power Supply Specifications
167
Performance Specifications
167
A/D Conversion Time
168
Temperature Measurement
168
Wiring
169
Terminal Layout
170
Applicable Cable and Terminal Tightening Torque
171
3.3 Power Supply Line
172
To Connect to FX Series PLC
172
To Connect to the FX 3UC Series PLC
172
Selection of Platinum Resistance Thermometer Sensor
173
Wiring of Platinum Resistance Thermometer Sensor
173
Grounding
173
Programming
174
Loading of A/D Conversion Data
174
List of Special Devices
175
Selection of Temperature Unit
175
Temperature Measurement
176
Number of Averaging Time
177
Error Status
178
Model Code
180
Example of Basic Program
180
Troubleshooting
181
PLC Version Number Check
181
Wiring Check
181
Special Device Check
181
Program Check
182
Error Status Check
182
Fx 3U
185
FX -4AD-TC-ADP (4-Channel Thermocouple Data Input)
186
Outline
187
Outline of Functions
187
Setup Procedure before Starting Operation
188
Connectable PLC and Its Version Number
189
Version Number of Compatible Programming Tool
189
Specifications
190
Generic Specifications
190
Power Supply Specifications
190
Performance Specifications
191
Temperature Measurement
192
Wiring
193
Terminal Layout
194
Applicable Cable and Terminal Tightening Torque
195
Power Supply Line
196
To Connect to FX Series PLC
196
To Connect to the FX 3UC Series PLC
196
Selection of Thermocouple
197
Thermocouple Type
197
Compensating Lead Wire
197
Wiring of Thermocouple
197
Wiring of Thermocouple Type K
197
Wiring of Thermocouple Type J
198
Caution Regarding Wiring
198
Programming
199
Loading of A/D Conversion Data
199
List of Special Devices
200
Selection of Temperature Unit
200
Selection of Type K or J
201
Temperature Measurement
201
Number of Averaging Time
202
Error Status
203
Model Code
205
Example of Basic Program
205
Troubleshooting
206
PLC Version Number Check
206
Wiring Check
206
Special Device Check
206
Program Check
207
Error Status Check
207
1 Outline
211
Outline of Function
211
Basic Operation Expressions in PID Instruction (Reference
212
How to Use PID Instruction
213
Explanation of Function and Operation
213
Relationship between Parameter Setting and Auto Tuning
214
Parameter
215
Parameter List: (S3) to (S3) + 28
215
Details of Parameters
217
Sampling Time (T ): (S3
217
Operation Setting (ACT):(S3)+1
218
Input Filter (Α): (S3)+2
220
Alarm Output Flag: (S3)+24
225
Auto Tuning
226
Limit Cycle Method
226
Parameters Set in Auto Tuning (of Limit Cycle Method
226
Auto Tuning Procedure
227
Reference: How to Obtain Three Constants in PID Control (Limit Cycle Method
228
Step Response Method
229
Parameters to be Set by Auto-Tuning (Step Response Method
229
Auto Tuning Procedure
229
Reference: How to Obtain Three Constants in PID Control (Step Response Method
230
Cautions on Auto Tuning Execution
230
Example of Practical Programs (for Step Response Method
231
Example: System and Operation
231
Program Example of Auto Tuning (Step Response Method) and PID Control
232
Program Example of Auto Tuning (Step Response Method
235
Troubleshooting
236
Error Codes
236
Warranty
239
Revised History
240
Mitsubishi MELSEC-F FX3U-4AD Installation Manual (3 pages)
Brand:
Mitsubishi
| Category:
Controller
| Size: 0.44 MB
Advertisement
Advertisement
Related Products
Mitsubishi MELSEC-F FX3U-4AD-ADP
Mitsubishi MELSEC-F FX3U-4AD-PT-ADP
Mitsubishi FX3U-4AD-PNK-ADP
Mitsubishi FX3U-4AD-PTW-ADP
Mitsubishi MELSEC-F FX3U-4AD-TC-ADP
Mitsubishi FX3U-4HSX-ADP
Mitsubishi FX3U-485-BD
Mitsubishi FX3U-422-BD
Mitsubishi FX3U-485ADP
Mitsubishi FX3U-485ADP(-MB)
Mitsubishi Categories
Air Conditioner
Controller
Projector
Automobile
Engine
More Mitsubishi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL