WARNING:
location. It has a separate protective earthing terminal on the chassis that must be
connected to earth ground permanently to ground the chassis adequately and protect
the operator from electrical hazards.
CAUTION:
attached an appropriate grounding lug to the grounding cable that you supply. Using a
grounding cable with an incorrectly attached lug can damage the router.
NOTE:
DC power supplies are shipped only in the redundant configuration of PTX10000 routers.
For details about different chassis configurations, see
on page 35
and PTX10016 Components and Configurations.
JNP10K-PWR-DC2 models can use the standard bus or the enhanced bus. The enhanced bus supports
the full 5500 W available from the JNP10K-PWR-DC2. The standard bus provides 3000 W for power
budget from the power management software. To determine whether your system has the standard power
bus or the enhanced power bus, see
JNP10K-PWR-AC Power Supply LEDs
The JNP10K-PWR-AC power supply has four LEDs on its faceplate: INP1, INP2, PWR OK, and FAULT.
These LEDs display information about the status of the power supply. See
The router is pluggable type A equipment installed in a restricted-access
Before you begin installing the router, ensure that a licensed electrician has
"PTX10000 Status Panel LEDs" on page
"PTX10008 Components and Configurations"
41.
Figure 33 on page
70
71.