PTX10000 Power System

IN THIS SECTION
JNP10K-PWR-DC2 Power Supply LEDs | 76
You can install up to six power supplies in a PTX10008 router in the slots labeled PEM 0 through PEM 5
(top to bottom) located in the rear of the chassis. In the PTX10016, you can install up to 10 power supplies
in the slots labeled PEM 0 through PEM 9 (top to bottom) located in the rear of the chassis.

JNP10K-PWR-AC Power Supply

The JNP10K-PWR-AC power supplies are 2700-W and support 200-240 VAC. The output is 12 VDC;
the output power is 2700 W.
CAUTION:
can coexist in the same chassis during the hot swap of AC for HVAC. Do not mix AC and
HVAC power supplies in a running environment.
WARNING:
location. It has a separate protective earthing terminal on the chassis that must be
connected to earth ground permanently to ground the chassis adequately and protect
the operator from electrical hazards.
Do not mix AC and DC power supplies in the same chassis. AC and HVAC
The router is pluggable type A equipment installed in a restricted-access
61