Juniper PTX10008 Hardware Manual page 167

Packet transport router
Hide thumbs Also See for PTX10008:
Table of Contents

Advertisement

How to Calculate the Number of Power Supplies Required for Your PTX10008 Configuration
Use this procedure to calculate the number of power supplies required by your router configuration. The
minimum power configuration for PTX10008 routers is three power supplies. However, using the calculated
minimum power configuration does not prevent the system from raising a power alarm. To ensure you do
not log power alarms, you must configure your router for n+1 power supplies.
To calculate the number of power supplies required for your minimum router configuration:
1. Determine the power available from the power supplies.
for installed power supplies.
NOTE:
DC systems are only supported in the redundant configuration.
Table 57: Total Power Available
Power Supply Module
Models
JNP10K-PWR-AC
JNP10K-PWR-AC2 dual
feed, high power (30-A)
setting
JNP10K-PWR-AC2 single
feed, high power (20-A)
setting
JNP10K-PWR-DC
JNP10K-PWR-DC2 dual
feed, high power (80-A)
setting
JNP10K-PWR-DC2 dual
feed, low power (60-A)
setting
JNP10K-PWR-DC2 single
feed, high power (80-A)
setting
With Three Power
Supplies
8100 W
16,500 W
15,000 W
Table 57 on page 169
shows the power available
With Four Power
Supplies
10,800 W
22,000 W
20,000 W
With Five Power
Supplies
13,500 W
27,500 W
25,000 W
12,500 W
27,500 W
22,000 W
13,750 W
169

Hide quick links:

Advertisement

Table of Contents
loading