Avaya Definity SI Maintenance Manual page 145

Table of Contents

Advertisement

System Features
An example of the Trunk Group Form Page 2 is shown in
.
GROUP MEMBER ASSIGNMENTS
1: B1901
2: B1902
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
Screen 5-5. Trunk Group Form — Simplex Mode (Page 2 of 5)
4. Locate the Tie Trunk port terminal connections at the cross-connect field.
See
Table 5-6 on page
5. At the cross-connect field, disconnect outside trunk facilities from the
Analog Tie Trunk ports and mark the disconnected wires for later when the
Tie Trunk ports are placed back into normal operation. The D Impact Tool
(AT-8762) is required to perform this step.
6. Use jumper wires (DT 24M-Y/BL/R/G) and the D Impact Tool to connect
wiring between the two ports assigned in Step 4 at the cross-connect field.
For example, if the two ports on the Analog Tie Trunk circuit pack are ports
1 and 2, connect the wirings as shown below:
7. Repeat Steps 13 through 16 of the E & M Mode Test Procedure.
555-233-123
TRUNK GROUP
Port
Name
5-38.
Port
1
T1
R1
T11
R11
ype
5
simplex
Mode
Type
simplex
type 5
simplex
type 5
Port
T12
R12
T2
R2
type
simplex
Issue 4 May 2002
Screen
5-5.
Page 2 of 5
Answer Delay
2
5
5-41

Advertisement