Drive Options And Peripheral Devices; Drive Options And Peripheral Devices - YASKAWA Z1000 User Manual

Ac drive for hvac fan and pump
Hide thumbs Also See for Z1000:
Table of Contents

Advertisement

6.2 Drive Options and Peripheral Devices

6.2

Drive Options and Peripheral Devices

Table 6.1
lists the names of the various peripheral devices, accessories, and options available for Yaskawa drives. Contact
Yaskawa or your Yaskawa agent to order these peripheral devices.
• Peripheral Device Selection: Refer to the Yaskawa catalog for selection and part numbers.
• Peripheral Device Installation: Refer to the corresponding option manual for installation instructions.
Option
AC Reactor
Modbus TCP/IP
SI-EM3
EtherNet/IP
SI-EN3
LONWORKS
SI-W3
UWR000051, 1 m cable
Remote Operator Cable
UWR000052, 2 m cable
USB Copy Unit
JVOP-181
Installation kit for mounting the drive with the heatsink outside of the panel.
Attachment for External
NEMA 1, UL Type 1 and NEMA 12, UL Type 12 attachments are available. NEMA 12, UL Type 12 attachments are
Heatsink
available only for rev. B products or later.
IP20/NEMA 1, UL Type 1
EZZ021136A-H
Kit
IP20/NEMA 1, 4, 12; UL
Type 1, 4, 12 Blank Keypad
UUX0000526
Kit
IP20/NEMA 1, 4, 12; UL
Type 1, 4, 12 Yaskawa Logo
UUX0000527
Keypad Kit
24 V Power Supply
600 V Class: PS-A10HB Supplies the drive controller with 24 Vdc power during main power loss.
DriveWizard Industrial
Contact Yaskawa
DriveWorksEZ
Contact Yaskawa
246
Table 6.1 Available Peripheral Devices
Model Number
Protects the drive when operating from a large power supply and improves the power factor by
suppressing harmonic distortion. Highly recommended for power supplies that exceed 600 kVA.
Communication Option Cards
Connects to a Modbus TCP/IP network.
Connects to an EtherNet/IP network.
Connects to a LONWORKS network.
RJ-45, 8-pin straight through, UTP CAT5e, extension cable (1 m or 2 m) to connect the HOA
keypad for remote operation
• Allows the user to copy and verify parameter settings between drives
• Functions as an adapter to connect the drive to a USB port on a PC
Parts to make the drive conform to IP20/NEMA 1, UL Type 1 enclosure requirements.
Provides HOA keypad (JVOP-183, JVOP-183R) functionality on an enclosure designed for IP20/
NEMA 1, 3R, 4, 4X, 12; UL Type 1, 3R, 4, 4X, 12, or IPo6 environment. This keypad has a
blank label on the front.
Provides HOA keypad (JVOP-183, JVOP-183R) functionality on an enclosure designed for IP20/
NEMA 1, 3R, 4, 4X, 12; UL Type 1, 3R, 4, 4X, 12, or IPo6 environment. This keypad has a
Yaksawa brand label on the front.
PC tool for drive setup and parameter management
PC tool for enhanced programming of the drive
Power Options
Interface Options
Mechanical Options
Others
PC Software Tools
YASKAWA TOEP YAIZ1U 03B YASKAWA AC Drive – Z1000 User Manual
Description

Advertisement

Table of Contents
loading

Table of Contents