ELECTRICAL
Timing Check Procedures
1,
The ignition timing check hole is in the starter recoil/magneto housing. Remove the check plug.
NOTE: The ignition timing marks are stamped on the outside of the flywheel. Ignition timing must be inspected
with the engine at room temperature (68°F / 20° C).
2.
With the transmission in neutral, start the engine and set engine speed to 3000 +/- 200 RPM (3500
±
200 RPM
for EH42PL, EH50PL).
3.
Direct the timing light at the ignition timing check hole and check the ignition timing. NOTE: Do not allow the
engine to warm up. The timing will retard approximately 2° when the engine is warm.
If the ignition timing is not within the specified range, adjust the stator plate position as described below.
Flywheel
Rotation
All Engines
EC38-PL
Flywheel
25.5 Rotation
23.5
1.
Remove the magneto housing.
2.
Remove the flywheel.
All EC25PFE- 09
and EC28PF(E)-01
EH42PL,
EH50PL
3.
Loosen the stator plate screws and adjust the stator plate position. NOTE: Moving the stator plate clockwise
retards (delays) the ignition timing. Moving the plate counterclockwise advances it.
7/96
10.10
Polaris Industries Inc.