Fuel Cut Operation; A/C Condenser Fan Control System; A/C Condenser Fan - Suzuki Jimny Service Manual

Jimny suzuki
Hide thumbs Also See for Jimny:
Table of Contents

Advertisement

Fuel cut operation

INSPECTION
NOTE:
Before inspection, check to make sure that gear shift
lever is in neutral position (with A/T model, selector lever
in "P" range), A/C is OFF and that parking brake lever is
pulled all the way up.
1) Warm up engine to normal operating temperature.
2) While listening to sound of injector (1) by using sound scope
(2) or such, increase engine speed to higher than 3,000 r/
min.
3) Check to make sure that sound to indicate operation of injec-
tor stops when throttle valve is closed instantly and it is
heard again when engine speed is reduced to less than
about 2,000 r/min.

A/C condenser fan control system

SYSTEM INSPECTION
WARNING:
Keep hands, tools, and clothing away from A/C con-
denser fan to help prevent personal injury. This fan is
electric and can come on whether or not the engine is
running. The fan can start automatically in response to
the ECT sensor with the ignition switch in the "ON" posi-
tion.
Check system for operation referring to "Flow Table B-7" in Sec-
tion 6.
If A/C condenser fan fails to operate properly, check relay, A/C
condenser fan and electrical circuit.

A/C condenser fan

INSPECTION
1) Check continuity between each two terminals.
If there is no continuity, replace A/C condenser fan motor.