Suzuki Jimny Service Manual page 386

Jimny suzuki
Hide thumbs Also See for Jimny:
Table of Contents

Advertisement

SCAN TOOL DATA
∆ ✱ ✱ ✱ ✱ O2S B1 S2 (HEATED OXY-
GEN SENSOR-2)
∆ ✱ ✱ ✱ ✱ PSP SW
DESIRED IDLE
(DESIRED IDLE SPEED)
TP SENSOR VOLT
(THROTTLE POSITION
SENSOR OUTPUT VOLT-
AGE)
INJ PULSE WIDTH (FUEL
INJECTION PULSE
WIDTH)
IAC FLOW DUTY (IDLE
AIR CONTROL FLOW
DUTY)
TOTAL FT B1
BATTERY VOLTAGE
CANIST PRG DUTY
(EVAP CANISTER PURGE
FLOW DUTY)
CLOSED THROT POS
(CLOSED THROTTLE
POSITION)
FUEL CUT
A/C CONDENSER FAN
ELECTRIC LOAD
A/C SWITCH
PNP SIGNAL (PARK / NEU-
TRAL POSITION SIGNAL)
A/T only
EGR VALVE
FUEL TANK LEVEL
BAROMETRIC PRESS
FUEL PUMP
CONDITION
When engine is running at 2000 r/min. for
3 min or longer after warming up.
No load to power steering.
At idling with no load after warming up, M/T
at neutral, A/T at "P" range
Throttle valve fully closed
Ignition switch
ON / engine
Throttle valve fully open
stopped
At specified idle speed with no load after
warming up
At 2500 r/min with no load after warming up
At idling with no load after warming up
At specified idle speed after warming up
Ignition switch ON / engine stop
Throttle valve at idle position
Throttle valve opens larger than idle posi-
tion
When engine is at fuel cut condition
Other than fuel cut condition
Ignition switch
A/C not operating
ON
A/C operating
Ignition switch ON / Headlight, small light,
heater fan and rear window defogger all
turned OFF
Ignition switch ON / Headlight, small light,
heater fan or rear window defogger turned
ON
Engine running after warming up, A/C not
operating
Engine running after warming up, A/C oper-
ating
Selector lever in "P" or "N"
Ignition switch
position
ON
Selector lever in "R", "D",
"2" or "L" position
At specified idle speed after warming up
Within 3 seconds after ignition switch ON or
engine running
Engine stop at ignition switch ON.
ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-29
REFERENCE VALUES
M/T
A/T
More than 0.2 V
Less than 4.8 V
2.0 – 3.6 msec.
2.0 – 3.6 msec.
Display the barometric pres-
0.01 – 0.95 V
OFF
700 r/min
750 r/min
5 – 25 %
– 35 – +35 %
12 – 15 V
0 – 100 %
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
P/N Range
D Range
0 %
0 – 100 %
sure
ON
OFF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sn413